ARMING WITH C-BUS LIGHTING-LIKE APPLICATION "ON" COMMAND
Options P167E-P170E allow any combination of Area 1 or Area 2 to be armed using a lighting application ON command. These
Program options set the C-Bus Application Address and the Group Address of the Lighting Application. When an ON command
is received from these addresses, the different Area combinations will arm.
P167E
C-BUS ARM APPLICATION ADDRESS
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
56 (default lighting application).
NOTES
See P168E to P170E to set the Group
address needed to arm Areas.
This sets the application address for the C-Bus ON commands that can ARM the panel.
The Application Address has the range of 48 to 95 ($30 to $5F).
Enter a 2 digit number within this range to program the option.
PROGRAMMING SEQUENCE:
Press P167E xxE (xx = 48 to 95)
P168E
C-BUS ARM AREA 1 GROUP ADDRESS
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
255 (no address).
NOTES
1. Area 1 will only arm if zones have
been assigned to it. See option P45E in
the 5400/16CB Installation Manual.
2. The shortcut Area 1 arming option
P62E 5E must be ON.
This sets the Group address for the C-Bus ON command that can ARM Area 1 of the panel.
Enter a 3 digit number between 0 to 255 to set the address. An address of 255 will turn OFF the option.
The P167E Application Address may also have to be set if the default application is not being used.
PROGRAMMING SEQUENCE:
Press P168E xxxE (xxx = 000 to 255)
P169E
C-BUS ARM AREA 2 GROUP ADDRESS
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
255 (no address).
NOTES
1. Area 2 will only arm if zones have
been assigned to it. See option P46E in
the 5400/16CB Installation Manual.
2. The shortcut Area 2 arming option
P62E 6E must be ON.
This sets the Group address for the C-Bus ON command that can ARM Area 2 of the panel.
Enter a 3 digit number between 0 to 255 to set the address. An address of 255 will turn OFF the option.
The P167E Application Address may also have to be set if the default application is not being used.
PROGRAMMING SEQUENCE:
Press P169E xxxE (xxx = 000 to 255)
P170E
C-BUS ARM AREA 1 & AREA 2 GROUP ADDRESS
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
255 (no address).
NOTES
1. Area 1 and Area 2 will only arm if
zones have been assigned to them.
See option P45E and P46E in the
5400/16CB Installation Manual.
2. The shortcut Area 1 and Area 2
arming options P62E 5E and 6E must
be ON.
3. This arms using the C-Bus User Code
(User 56), which must be set up to allow
Area 1 and/or Area 2 arming.
This sets the Group address for the C-Bus ON command that can ARM Area 1 and/or Area 2 of the
panel. Enter a 3 digit number between 0 to 255 to set the address. An address of 255 will turn OFF the
option.
The P167E Application Address may also have to be set if the default application is not being used.
PROGRAMMING SEQUENCE:
Press P170E xxxE (xxx = 000 to 255)
To program User Code 56 for Area1 & Area2 arming.
In installer program mode, press P256E EXCLUDE E 1E 2E