C-BUS TRAINING MANUAL - VOL 2
26
Icon Function
Hide Project Manager Hides the Project Manager, providing more room for the Units windows.
Add Unit Adds a new unit to the database. You are prompted to select a unit from a list of
known unit types. You can then enter a Serial Number, Unit Address and Name (tag)
for the unit.
Delete Unit Deletes a unit from the database.
All to Network Transfers the congureuration data of all units in the Database to units of the same
type with the same Unit Address on the Network.
Get Serials Transfers serial numbers of all units on the Network to units of the same type and
Unit Address in the Database.
Doc. Creates a le listing each unit in the database including its Part Name, Unit Type, and
Unit, Application, Area and Group Addresses. The data is written in ASCII Comma
Separated Value (CSV) format, suitable for use in a spreadsheet.
Edit Unit Presents you with a panel allowing you to congure the unit’s Application Address,
Group Address and many other parameters (depending on the unit type).
Unit -> Network Transfers the congureuration data of the selected unit in the Database to a unit of
the same type with the same Unit Address on the Network.
Copy Unit Make a copy of the selected unit.
Readdress Prompts you to select a new Unit Address for the selected unit.
Reinstall Transfers the congureuration data from a unit on the Network with a Unit Address
of 255, to the selected unit of the same type in the Database. It is not necessary to
use the “Scan Network” function in the “Units on Network” window rst.
Table 9 – Units in Database window icon functions
Icon Function
Scan Network Performs a complete scan of a connected C-Bus
®
Network. If multiple units have
the same Unit Address, you will be asked if you want to resolve the Unit Address
conict (unravel). Scanned units are loaded into the “Units on Network” window.
Scan New Performs a short scan of a connected C-Bus Network to search for units with a Unit
Address that is not present in the “Units on Network” window. Units with a duplicate
Unit Address will not be detected.
Ping Checks the C-Bus Network to see if the units present in “Units on Network” exist.
Add Unit -> DB Adds the selected unit on the Network to the Database (only if the Database has no
unit with the same Unit Address or serial number).
Set Addr. -> DB Changes the Unit Address of the selected unit to that of a compatible unit in the
Database.
Match Serials Changes the Unit Addresses of units on the Network to the Unit Addresses of units
in the database which have the same serial number. You are prompted with a list of
units so you can select which Addresses to change.
Readdress Prompts you to select a new Unit Address for the selected unit.
Unravel Checks the C-Bus Network for multiple units with the same Unit Address. If
duplicates are found you will be asked if you want to resolve the conflict (unravel).
All Units -> DB Transfers the configureuration data of all units on the Network to units of the same
type with the same Unit Address in the Database. Any units not present in the
Database will be added.
Unit -> DB Transfers the configureuration data of the selected unit to a unit of the same type
with the same Unit Address in the Database.
Make Network(When
bridge selected)
Creates, configures and opens a new Network corresponding to the other side of
the selected bridge or gateway.
Table 10 – Units on Network window icon functions